Accuracy Analysis of Fluid Volume Measurement And Calculation Methods on Multislice Computed Tomography Radiology
Main Article Content
Abstract
Background: Multislice Computed Tomography (MSCT) is utilized for the measurement of bleeding volume in hemorrhagic stroke patients. This is very necessary to determine the right medical action. Errors in measurement can lead to suboptimal medical measures taken. Objective: to analyze the measurement and calculation of fluid volume by automatic and manual methods on the volume of fluid contained in the phantom on MSCT. Methods: The type of research is quantitative experimental with the sample used is a phantom made of polyethylene (Dacron) filled with irregular milk liquid as much as 10 volume variations. The research instruments used were worksheets and interview sheets. Data processing and analysis are descriptive by getting the average value. Results: Measurement and calculation of irregular volume of 10 ml, 20 ml, 30 ml, 40 ml, 50 ml, 60 ml, 70 ml, 80 ml, 90 ml, and 100 were done automatically on the CT scan plane and manually using the formula ½ A x B x C. The automatic method had an average volume difference of 1.39% and the manual method had an average volume difference of 6.88%. The automatic method has a small volume difference. Conclusion: the measurement and calculation of volume with the automatic method has a better accuracy value than the manual method. The results of these measurements and calculations are highly dependent on the accuracy of precise segmentation techniques on the object.
Article Details
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
References
Karthikeyan D. Step by Step Ct Scan. New Delhi: Jaypee Brothers Medical Publishers (P) Ltd.; 2018
PENGDA DKI JAKARTA P. Teknik Pemeriksaan CT Scan. Jakarta: Pari Jaya. 2016
Bushong SC. Radiologic Science For Technologists. Eleventh. St. Louis: Elsevier, Inc; 2017.
Ballinger PW. Merrill’s Atlas of Radiographic Positions & Radiologic Procedures. Tenth. St. Louis: Mosby Company; 2014.
Morcos SK WJ. Multislice CT. Third. Berlin: Springer. 2004
Saefudin T, Hidayat EPSH W. Pengukuran Volume Perdarahan Otak Dengan CT Scan. First. Jakarta: TRUSTCO; 2014. 2014
Wulandari selly oktaviana wulandari. Hubungan Volume Perdarahan Berdasarkan Ct-Scan Dengan. Cimahi; 2019. 2019
Sholiha A, Sukmaningtyas H PD. Korelasi Antara Volume Perdarahan Intraserebral Dengan Nilai Indeks Barthel Pada Stroke Hemoragik. J Kedokt Diponegoro. 2016;275–286.
Kiswoyo AS, Wibowo GM FW. Penghitungan Volumetrik Perdarahan dengan Metode Volume Automatik (Software Volume Evaluation) dan Metode Manual (Broderick) pada MSCT Kepala (Study Eksperimen pada Pasien Perdarahan Intraserebral di RS. Haji Surabaya). J Imejing Diagnostik. 2017
Halim K. Analisa Pengukuran Volume Perdarahan Pada Phantom Dengan Dual Source Computed Tomography Di Rumah Sakit Umum Pusat Nasional Dr. Cipto Mangunkusumo Jakarta. Jakarta. 2013
Rizki NI. Analisis Pengukuran Prototype Volume Cairan Secara Manual dan Digital Menggunakan Pesawat Computed Tomography Scan. 2016